Summary:The electric spray pressure is insufficient and the atomization is not good: if the water inlet ball valve is suspended ...

The electric spray pressure is insufficient and the atomization is not good: if the water inlet ball valve is suspended by dirt, remove the water inlet valve and remove the dirt with a cloth; if the leather bowl is damaged, replace the new leather bowl; if the connection part is not Install the sealing ring, or leak the gas due to the damage of the sealing ring. You can install or replace the sealing ring. Spray can not be fogged: if the oblique hole of the nozzle body is blocked by dirt, the oblique hole can be dredged; if the obstruction of the nozzle hole is blocked, the nozzle can be disassembled and cleaned, but hard objects such as iron wire or copper needles can not be used to prevent the hole from expanding. To make the spray quality worse; if the filter in the casing is blocked or the ball of the water valve is suspended, the filter and the dirt on the small ball should be cleaned.

Or see if the switch is leaking or cannot be screwed. If the switch cap is not tightened, tighten the switch cap; if the gasket on the switch core is worn, replace the gasket; the switch cannot be screwed because it has been left for a long time or has been used. For a long time, the switch core is stuck due to the erosion of the agent, and the parts should be removed and cleaned in kerosene or diesel; if it is difficult to remove, it can be immersed in kerosene for a period of time, and then disassembled to remove it. Do not use hard objects beat.

Then look at the water leakage at each connection. If the joint is loose, tighten the nut; if the gasket is not flat or damaged, flatten the gasket or replace the gasket; if the gasket shrinks and hardens, immerse it in animal oil Use after softening.